我司代理韓國(guó)工控工業(yè)自控元器件、儀器儀表、開(kāi)關(guān)按鈕 低壓電器 工廠自動(dòng)化工程 電力電工數(shù)顯表 韓國(guó)龍聲電機(jī)株式會(huì)社(YongSung Electric CO;ltd)中國(guó)*代理 日本株式會(huì)社派特萊(Patlite)信號(hào)燈 HANYOUNG(韓榮電子) 德國(guó)WERMA signaltechink(偉馬快德)中國(guó)*銷(xiāo)售商 AUTONICS(奧托尼克斯) KOINO(建興) KACON(開(kāi)控) YONGSUNG(韓國(guó)龍聲) Q.LIGHT(克萊特-警報(bào)燈) EOCR(韓國(guó)三和電機(jī)保護(hù)器) HEDSS(海德)旋轉(zhuǎn)編碼器 WOONYOUNG(云永) METRONIX(脈超尼斯/麥特斯) DAEYANG(大洋) KWANGWOO(光宇) TEND(天得電機(jī)) RKC(理化溫控) FOTEK(陽(yáng)明工控) OMRON(日本歐姆龍) MOUJEN(中國(guó)臺(tái)灣茂仁) SUNX(日本神視) SICK(德國(guó)施克) 韓國(guó)MENICS 韓國(guó)KONICS 美國(guó)HONEYWELL(霍尼韋爾) LG低壓電器 SAMYOUNG(韓國(guó)三榮) SUNHO(韓國(guó)成浩) SUNKWAN(韓國(guó)鮮光) FOX(DAESUNG韓國(guó)大成) 韓國(guó)FAS、 DongA(東亞機(jī)電) Daeil大一 CHANTO(中國(guó)臺(tái)灣長(zhǎng)拓) 日本SMC氣動(dòng) 中國(guó)臺(tái)灣HIWIN直線導(dǎo)軌 法國(guó)高諾斯(Crouzet) 日本和泉(IDEC) 德國(guó)P+F倍加福(PEPPERL+FUCHS) 中國(guó)臺(tái)灣ANLY(安良機(jī)電) 中國(guó)臺(tái)灣SAMD(山電電機(jī)) HIBOX(韓國(guó)海博開(kāi)關(guān)盒/接線盒) 等等
溫控表:計(jì)數(shù)器:旋轉(zhuǎn)警報(bào)器:液位開(kāi)關(guān)
NameDIGITALMETERModel2L-DM-AInputVoltageAC220V(100Vseparateorder)Input0~1
2L-DM-A 2L-DM-V數(shù)字式液位顯示儀表 產(chǎn)品信息
 


 

Name

DIGITAL
METER

Model

2L-DM-A

 Input Voltage

AC220V(100V
separate order)

Input

0~1.5V(%)

output

DC24V(4/20mA)

Function

Level Indicator

Panel CUT

92×45

SIZE

98×50×102

(H×W×D)

Name

DIGITAL
METER

Model

2L-DM-V

 Input Voltage

AC220V(100V
separate order)

Input

0~1.5V(%)

output

4~20mA

Function

Level Indicator

Panel CUT

92×45

SIZE

98×50×102

(H×W×D)

Model

2L-LIC-D/P
(
Resistance Input)

Input Voltage

AC 220V (100V
separate order)

Contact Point
Capacity

CONTROL AC 220V 5A

HI/LO AC 220V 3A

Feature

Resistance Input Method(0~300Ω)

Function

Indication , water supply/draining automation and alarm for high/low water level in various kind of tank

Panel CUT

92×45 / 98×50×102

Material

- HEAD  - Nylon Fiber

- FLOAT- P/P foaming

- PIPE   - SUS 304

Model

2L-LIC-D/P
(
Current Input)

Input Voltage

AC 220V (100V
separate order)

Contact Point
Capacity

CONTROL AC 220V 5A

HI/LO AC 220V 3A

Feature

Current Input (4~20mA)

Function

Indication , water supply/draining automation and alarm for high/low water level in various kind of tank

Panel CUT

92×45 / 98×50×102

Material

- HEAD  - Nylon Fiber

- FLOAT- P/P foaming

- PIPE   - SUS 304

 

2L-LIC-D/P is the Digital Level Indicating Controller built in a Micom Chip, it can check the indicating value as setting High/Low level alarm and Auto Feeding/Drainage for various kinds of tanks as Digital Mode.  It is the Resistance Input (0~300Ω) Type of level controller built in the function isolating a contact  output in case of the line disconnecting or the abnormal condition of sensor.

Composed easy to control and set-up, it is manufactured to operate strongly against the power noise or the induction of sensor line, etc.

 

(Resistance Input)

Using power  :  AC 220V 60HZ 2W (Special order - 100V)

Contact Capacity  :  5A MAX(LO-AL/HI-AL/Feeding. Drainage Contact)

Control Output  :  Contact of Feeding. Drainage, LO-AL, HI-AL, 4/20mA)

Input Signal  :  0-300Ω Resistance(Indicating Meter Sensor & Parallel mode)

Error  :  ±0.5FS

Operating condition  :  0~50℃   0~80%RH

Outer dimension  : 98×50×102(H×W×D) CUT/92×45

Usage  :  Level indicating Controller for various kinds of Water tanks, Oil tank, etc
              Sensor is required to use with less than 80℃
              (Separate order for more than 80℃)

 

MODE

When pressing a Mode upon setting up, LED Lamp lights in order;LO-AL>START>STOP>HI-AL

Indicating Limit

0%~120% (In case of more than 120%, 'hid' flickers) (0%~99%)

DN

Using to decrease the setting value in the position of LED Lamp required

hid

In case of line disconnecting, the abnormal condition of sensor or 99% setting is not exact, it flickers

UP

Using to increase the setting value in the position of LED Lamp required

Setting limit

0%~120% (LO-AL/HI-AL/START/STOP)

ENT

After setting values in the setting position of each Mode, press an ENT.  All are remembered.

Sensor Input

Voltage mode 0~1.5V (Indicating meter) by a Resistance Input(0~300Ω)

Reference

If not press an ENT for 5 sec., it returns to the original display position

With the first delivery, LO-AL(40%), START(60%), STOP(80%), HI-AL(90%) are set

When 'hid' flickers, the function of mode won't work.
 
 
 

Reference

Indicating meter can be connected up to 3 units by Parallel Mode with a Sensor terminal (0~1.5V)

4~20mA Output Terminal builds in a card (Option) when ordering. (Separate setting or insert is possible)

Set 99% numeric value as putting a sensor float in 99% position and adjusting 99% set in a unit.

 

2L-LIC-D/P is the Digital Level Indicating Controller built in a Micom Chip, it can check the indicating value as setting High/Low level Alarm and Auto Feeding/Drainage for various kinds of tanks as Digital Mode.  It is the Current Input (4-20MA) Type of Level Controller built in the function isolating contact output in case of line disconnecting, short or the abnormal condition of sensor.

Composed easy to control and set-up, it is manufactured to operate strongly against the power noise or the induction of sensor line, etc

 

(Current Input)

Using power  :  AC 220V 60HZ 2W (Special order - 100V)

Contact Capacity  :  5A MAX(LO-AL/HI-AL/Feeding. Drainage Contact)

Control Output  :  Contact of Feeding. Drainage, LO-AL, HI-AL)

Input Signal  :  4-20MA (Indicating Meter & Sensor Series mode)

Error  :  ±0.5FS

Operating condition  :  0~50℃   0~80%RH

Outer dimension  :  98×50×102(H×W×D) CUT/92×45

Usage  :  Level indicating Controller for various kinds of Water tanks, Oil tank,
              etc Sensor is required to use with less than 80℃
              (Separate order for more than 80℃)

 

MODE

When pressing a Mode upon setting up, LED Lamp lights in order;LO-AL>START>STOP>HI-AL

Indicating Limit

-3% - 120% (In case of less than -3%, 'oPn' flickers, more than 120%, 'hid' flickers) (0%~99%)

DN

Using to decrease the setting value in the position of LED Lamp required

hid

In case of more than 120%(more than 20mA, or the abnormal of sensor), it flickers

oPn

It flickers in -3% (Less than 4mA or the abnormal of sensor).
(When sensor isn't connected)

UP

Using to increase the setting value in the position of LED Lamp required

Setting limit

0%~120% (LO-AL/HI-AL/START/STOP)

ENT

After setting values in the setting position of each Mode, press an ENT.  All are remembered.

Sensor Input

Current mode (Indicating meter 4~20mA series mode) by Current Input(4~20mA)

Reference

If not press an ENT for 5 sec., it returns to the original display position

With the first delivery, LO-AL(40%), START(60%), STOP(80%), HI-AL(90%) are set

When 'hid' flickers, the function of mode won't work.

Reference

Indicating meter for 4~20mA use should be connected with a sensor by Series Mode
(Line Resistance 700ΩMAX)

 

Regulate 0~99%, adjusting SPAN and ZERO inside of a Sensor Head

Fill the existence of pressure such as non-pressure tank, pressure tank(less than 5 kg) according to the classes of tanks and separate entry is required if temperature is high (more than 80℃).  (Special order in case of more than 5K)

There are two types; Flange and Screw type.  In case of a Flange type, it should use with 3″(80Φ)4″(100Φ), In case of a Screw type, 2″(50Φ) socket should be welded to a tank.

Separate order is required for special chemicals and high temperature use.
(80℃ and more)

 

 

Gear-type Sensor
 

 

 

Flexible Sensor
 

As Gear-type sensor hasn't the height of ceiling,  it is ordered and manufactured as a Gear-type when sensor isn't able to put in a tank.

Refer to the Gear-Type in the tail of 35~36 page

Temperature should be less than 80℃ only (Oil, Water, etc)

Special order is required for the chemicals tank such Hydrochloric acid, Sulphuric acid

 

 

 

 

 

 

 

 [Attention!] Never use to a Pressure tank

As Flexible-type sensor hasn't the height of ceiling, it is ordered and manufactured as a Flexible-type when sensor isn't able to put in a tank.

In the lower part of sensor, the stain weight is an one-touch fitting.  Simple to put a hose in (50mm/m socket-type).

When handling a sensor, Put a stain weight in first and continue to put with care while remaining a sensor as the original position. (Be careful not to be bent)

When delivering, deliver as a fixed position to the handling frame (PVC Pipe) and Do not give an impulse or throw.
(It can be the reason of damage)

Temperature should be less than 80℃ only (Oil, Water, etc)

 

[Attention!] Never use to a Pressure tank